Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 97
Filtrar
1.
Respir Res ; 25(1): 56, 2024 Jan 24.
Artículo en Inglés | MEDLINE | ID: mdl-38267944

RESUMEN

BACKGROUND: MRproANP and COPAVP are prognostic markers for mortality in chronic obstructive pulmonary disease (COPD). Furthermore, these biomarkers predict mortality due to cardiovascular diseases, which are important prognostically determining comorbidities in patients with COPD. However, less is known about these biomarkers in recently diagnosed mild to moderate COPD. Therefore, we analyzed these biomarkers as potential predictors of mortality in recently diagnosed mild to moderate COPD. METHODS: The blood biomarkers considered were copeptin (COPAVP), midregional adrenomedullin (MRproADM), midregional proatrial naturetic peptide (MRproANP), and fibrinogen. Analyses were performed in patients with stable "recently diagnosed mild to moderate COPD" defined by GOLD grades 0-2 and diagnosis of COPD ≤ 5 years prior to inclusion into the COSYCONET cohort (COPD and Systemic Consequences-Comorbidities Network), using Cox regression analysis with stepwise adjustment for multiple COPD characteristics, comorbidities, troponin and NT-proBNP. RESULTS: 655 patients with recently diagnosed mild to moderate COPD were included. In the initial regression model, 43 of 655 patients died during the 6-year follow-up, in the final model 27 of 487. Regression analyses with adjustment for confounders identified COPAVP and MRproANP as statistically robust biomarkers (p < 0.05 each) of all-cause mortality, while MRproADM and fibrinogen were not. The fourth quartile of MRproANP (97 pmol/L) was associated with a hazard ratio of 4.5 (95%CI: 1.6; 12.8), and the fourth quartile of COPAVP (9.2 pmol/L) with 3.0 (1.1; 8.0). The results for MRproANP were confirmed in the total cohort of grade 0-4 (n = 1470 finally). CONCLUSION: In patients with recently diagnosed mild to moderate COPD, elevated values of COPVP and in particular MRproANP were robust, independent biomarkers for all-cause mortality risk after adjustment for multiple other factors. This suggests that these markers might be considered in the risk assessment of early COPD.


Asunto(s)
Enfermedades Cardiovasculares , Glicopéptidos , Enfermedad Pulmonar Obstructiva Crónica , Humanos , Biomarcadores , Fibrinógeno , Enfermedad Pulmonar Obstructiva Crónica/diagnóstico
2.
Eur J Med Res ; 28(1): 568, 2023 Dec 06.
Artículo en Inglés | MEDLINE | ID: mdl-38053110

RESUMEN

BACKGROUND: In 2022/2023, Influenza A and Respiratory Syncytial Virus (RSV) reappeared in hospitalized patients, which was in parallel to ongoing SARS-CoV-2 infections. The aim of our study was to compare the characteristics and outcomes of these infections during the same time. METHODS: We included patients of all ages with a positive polymerase chain reaction (PCR) test for Influenza A/B, RSV, or SARS-CoV-2 virus hospitalized in the neurological, internal or paediatric units of the RoMed Hospital Rosenheim, Germany, between October 1st 2022 and February 28th 2023. RESULTS: A total of 906 patients were included (45.6% female; median age 68.0 years; 21.9% Influenza A, 48.2% SARS-CoV-2, 28.3% RSV). Influenza B (0.2%) and co-infections (1.5%) played a minor role. In patients aged ≥ 18 years (n = 637, 71%), Influenza A, SARS-CoV-2 and RSV groups differed in age (median 72, 79, 76 years, respectively; p < 0.001). Comorbidities, particularly asthma and COPD, were most prevalent for RSV. 103 patients were admitted to the intensive care unit (ICU) (16.3% Influenza A, 15.3% SARS-CoV-2, 19.2% RSV; p = 0.649), 56 died (6.8% Influenza A, 9% SARS-CoV-2, 11.1% RSV; p = 0.496). RSV showed the highest frequencies of low-flow oxygen supplementation for admission and stay. Differences in the length of stay were minor (median 7 days). Conversely, in patients aged < 18 years (n = 261, 28,8%), 19.5%, 17.6% and 60.2% were in the Influenza A, SARS-CoV-2 and RSV groups, respectively; 0.4% showed Influenza B and 2.3% co-infections. 17 patients were admitted to ICU (3.9% Influenza A, 9.6% RSV, 0% SARS-CoV-2); none died. RSV showed the highest frequencies of high- and low-flow oxygen supplementation, SARS-CoV-2 the lowest. CONCLUSION: When comparing infections with Influenza, SARS-CoV-2 and RSV in the winter 2022/2023 in hospitalized adult patients, rates of ICU admission and mortality were similar. RSV showed the highest frequencies of obstructive airway diseases, and of oxygen supplementation. The latter was also true in children/adolescents, in whom RSV dominated. Thus, in the situation of declining importance of SARS-CoV-2, RSV showed a disease burden that was relatively higher than that from Influenza and SARS-CoV-2 across ages, and this might be relevant for the seasons coming.


Asunto(s)
COVID-19 , Coinfección , Gripe Humana , Infecciones por Virus Sincitial Respiratorio , Adulto , Niño , Adolescente , Humanos , Femenino , Anciano , Masculino , Virus Sincitiales Respiratorios , Gripe Humana/epidemiología , SARS-CoV-2 , Infecciones por Virus Sincitial Respiratorio/epidemiología , Infecciones por Virus Sincitial Respiratorio/terapia , Estaciones del Año , COVID-19/epidemiología , Atención Primaria de Salud
3.
NPJ Prim Care Respir Med ; 30(1): 32, 2020 07 30.
Artículo en Inglés | MEDLINE | ID: mdl-32732930

RESUMEN

Capnovolumetry performed during resting ventilation is an easily applicable diagnostic tool sensitive to airway obstruction. In the present analysis, we investigated in which way capnovolumetric parameters can be combined with basic anamnestic information to support the diagnosis of asthma and COPD. Among 1400 patients of a previous diagnostic study, we selected 1057 patients with a diagnosis of asthma (n = 433), COPD (n = 260), or without respiratory disease (n = 364). Besides performing capnovolumetry, patients answered questions on symptoms and smoking status. Logistic regression analysis, single decision trees (CHAID), and ensembles of trees (random forest) were used to identify diagnostic patterns of asthma and COPD. In the random forest approach, area/volume of phase 3, dyspnea upon strong exertion, s3/s2, and current smoking were identified as relevant parameters for COPD vs control. For asthma vs control, they were wheezing, volume of phase 2, current smoking, and dyspnea at strong exertion. For COPD vs asthma, s3/s2 was the primary criterion, followed by current smoking and smoking history. These parameters were also identified as relevant in single decision trees. Regarding the diagnosis of asthma vs control, COPD vs control, and COPD vs asthma, the area under the curve was 0.623, 0.875, and 0.880, respectively, in the random forest approach. Our results indicate that for the diagnosis of asthma and COPD capnovolumetry can be combined with basic anamnestic information in a simple, intuitive, and efficient manner. As capnovolumetry requires less cooperation from the patient than spirometry, this approach might be helpful for clinical practice.


Asunto(s)
Asma/diagnóstico , Pruebas Respiratorias/métodos , Dióxido de Carbono/análisis , Enfermedad Pulmonar Obstructiva Crónica/diagnóstico , Adulto , Anciano , Árboles de Decisión , Femenino , Humanos , Modelos Logísticos , Masculino , Anamnesis , Persona de Mediana Edad , Pruebas de Función Respiratoria/métodos
4.
Sci Rep ; 10(1): 10544, 2020 06 29.
Artículo en Inglés | MEDLINE | ID: mdl-32601330

RESUMEN

We studied whether in patients with stable COPD blood gases (BG), especially oxygenated hemoglobin (OxyHem) as a novel biomarker confer information on disease burden and prognosis and how this adds to the information provided by the comorbidity pattern and systemic inflammation. Data from 2137 patients (GOLD grades 1-4) of the baseline dataset of the COSYCONET COPD cohort were used. The associations with dyspnea, exacerbation history, BODE-Index (cut-off ≤2) and all-cause mortality over 3 years of follow-up were determined by logistic and Cox regression analyses, with sex, age, BMI and pack years as covariates. Predictive values were evaluated by ROC curves. Capillary blood gases included SaO2, PaO2, PaCO2, pH, BE and the concentration of OxyHem [haemoglobin (Hb) x fractional SaO2, g/dL] as a simple-to-measure correlate of oxygen content. Inflammatory markers were WBC, CRP, IL-6 and -8, TNF-alpha and fibrinogen, and comorbidities comprised a broad panel including cardiac and metabolic disorders. Among BG, OxyHem was associated with dyspnoea, exacerbation history, BODE-Index and mortality. Among inflammatory markers and comorbidities, only WBC and heart failure were consistently related to all outcomes. ROC analyses indicated that OxyHem provided information of a magnitude comparable to that of WBC, with optimal cut-off values of 12.5 g/dL and 8000/µL, respectively. Regarding mortality, OxyHem also carried independent, additional information, showing a hazard ratio of 2.77 (95% CI: 1.85-4.15, p < 0.0001) for values <12.5 g/dL. For comparison, the hazard ratio for WBC > 8000/µL was 2.33 (95% CI: 1.60-3.39, p < 0.0001). In stable COPD, the concentration of oxygenated hemoglobin provided additional information on disease state, especially mortality risk. OxyHem can be calculated from hemoglobin concentration and oxygen saturation without the need for the measurement of PaO2. It thus appears well suited for clinical use with minimal equipment, especially for GPs.


Asunto(s)
Oxihemoglobinas/metabolismo , Enfermedad Pulmonar Obstructiva Crónica/diagnóstico , Adulto , Anciano , Anciano de 80 o más Años , Biomarcadores/sangre , Análisis de los Gases de la Sangre , Femenino , Humanos , Inflamación/sangre , Masculino , Persona de Mediana Edad , Pronóstico , Enfermedad Pulmonar Obstructiva Crónica/sangre , Enfermedad Pulmonar Obstructiva Crónica/mortalidad , Índice de Severidad de la Enfermedad , Tasa de Supervivencia
5.
Respir Res ; 21(1): 28, 2020 Jan 20.
Artículo en Inglés | MEDLINE | ID: mdl-31959163

RESUMEN

BACKGROUND: Peripheral neuropathy is a common comorbidity in COPD. We aimed to investigate associations between alterations commonly found in COPD and peripheral neuropathy, with particular emphasize on the distinction between direct and indirect effects. METHODS: We used visit 4 data of the COPD cohort COSYCONET, which included indicators of polyneuropathy (repeated tuning fork and monofilament testing), excluding patients with diabetes a/o increased HbA1c. These indicators were analysed for the association with COPD characteristics, including lung function, blood gases, 6-min walk distance (6-MWD), timed-up-and-go-test (TUG), exacerbation risk according to GOLD, C-reactive protein (CRP), and ankle-brachial index (ABI). Based on the results of conventional regression analyses adjusted for age, BMI, packyears and gender, we utilized structural equation modelling (SEM) to quantify the network of direct and indirect relationships between parameters. RESULTS: 606 patients were eligible for analysis. The indices of polyneuropathy were highly correlated with each other and related to base excess (BE), ABI and TUG. ABI was linked to neuropathy and 6-MWD, exacerbations depended on FEV1, 6-MWD and CRP. The associations could be summarized into a SEM comprising polyneuropathy as a latent variable (PNP) with three measured indicator variables. Importantly, PNP was directly dependent on ABI and particularly on BE. When also including patients with diabetes and/or elevated values of HbA1c (n = 742) the SEM remained virtually the same. CONCLUSION: We identified BE and ABI as major determinants of peripheral neuropathy in patients with COPD. All other associations, particularly those with lung function and physical capacity, were indirect. These findings underline the importance of alterations of the micromilieu in COPD, in particular the degree of metabolic compensation and vascular status.


Asunto(s)
Polineuropatías/epidemiología , Polineuropatías/fisiopatología , Enfermedad Pulmonar Obstructiva Crónica/epidemiología , Enfermedad Pulmonar Obstructiva Crónica/fisiopatología , Anciano , Índice Tobillo Braquial/tendencias , Estudios de Cohortes , Comorbilidad , Estudios Transversales , Femenino , Alemania/epidemiología , Humanos , Masculino , Persona de Mediana Edad , Polineuropatías/diagnóstico , Enfermedad Pulmonar Obstructiva Crónica/diagnóstico
6.
Respir Med ; 154: 18-26, 2019.
Artículo en Inglés | MEDLINE | ID: mdl-31203096

RESUMEN

RATIONALE: Alterations of acid-base metabolism are an important outcome predictor in acute exacerbations of COPD, whereas sufficient metabolic compensation and adequate renal function are associated with decreased mortality. In stable COPD there is, however, only limited information on the combined role of acid-base balance, blood gases, renal and respiratory function on exacerbation risk grading. METHODS: We used baseline data of the COPD cohort COSYCONET, applying linear and logistic regression analyses, the results of which were implemented into a comprehensive structural equation model. As most informative parameters it comprised the estimated glomerular filtration rate (eGFR), lung function defined via forced expiratory volume in 1 s (FEV1), intrathoracic gas volume (ITGV) and (diffusing capacity for carbon monoxide (DLCO), moreover arterial oxygen content (CaO2), partial pressure of oxygen (PaCO2), base exess (BE) and exacerbation risk according to GOLD criteria. All measures were adjusted for age, gender, body-mass index, the current smoking status and pack years. RESULTS: 1506 patients with stable COPD (GOLD grade 1-4; mean age 64.5 ±â€¯8.1 y; mean FEV1 54 ±â€¯18 %predicted, mean eGFR 82.3 ±â€¯16.9 mL/min/1.73 m2) were included. BE was linked to eGFR, lung function and PaCO2 and played a role as indirect predictor of exacerbation risk via these measures; moreover, eGFR was directly linked to exacerbation risk. These associations remained significant after taking into account medication (diuretics, oral and inhaled corticosteroids), whereby corticosteroids had effects on exacerbation risk and lung function, diuretics on eGFR, BE and lung function. CONCLUSION: Even in stable COPD acid-base metabolism plays a key integrative role in COPD risk assessment despite rather small deviations from normality. It partially mediates the effects of impairments in kidney function, which are also directly linked to exacerbation risk.


Asunto(s)
Desequilibrio Ácido-Base/complicaciones , Enfermedad Pulmonar Obstructiva Crónica/sangre , Enfermedad Pulmonar Obstructiva Crónica/fisiopatología , Desequilibrio Ácido-Base/metabolismo , Anciano , Análisis de los Gases de la Sangre , Monóxido de Carbono/metabolismo , Estudios de Cohortes , Comorbilidad , Estudios Transversales , Progresión de la Enfermedad , Femenino , Volumen Espiratorio Forzado , Tasa de Filtración Glomerular/fisiología , Humanos , Pruebas de Función Renal , Masculino , Persona de Mediana Edad , Presión Parcial , Capacidad de Difusión Pulmonar/fisiología , Enfermedad Pulmonar Obstructiva Crónica/epidemiología , Pruebas de Función Respiratoria , Medición de Riesgo/métodos
7.
Respir Physiol Neurobiol ; 258: 40-46, 2018 12.
Artículo en Inglés | MEDLINE | ID: mdl-30261306

RESUMEN

We investigated acute effects of inhalation of hypertonic saline solution (HSS) and oxygen (O2, control exposure) on pulmonary diffusing capacity for nitric oxide (DLNO) and carbon monoxide (DLCO). In a randomized crossover study, 20 healthy, non-smoking subjects were allocated to short-term inhalation of HSS or O2. Spirometry [(forced expiratory volume in 1 s (FEV1) and forced vital capacity (FVC)] and combined single-breath DLNO-DLCO measurements were performed before and immediately after inhalation of either HSS or O2. Percent changes were presented as median values (interquartile range). After HSS inhalation, DLNO, FEV1 and FVC were decreased by -3.0% (-7.3, 0.5), -3.1% (-4.2, -1.6) and -1.2% (-3.3, 0.6), respectively (all P < 0.05), without significant effect on DLCO. No changes in spirometry and diffusing capacity were observed following O2 inhalation. Acute inhalation of HSS causes a slight decrease in membrane conductance, probably as a result of fluid imbalance at the alveolar surface and interstitial fluid accumulation, both of which could impair gas exchange.


Asunto(s)
Óxido Nítrico/metabolismo , Capacidad de Difusión Pulmonar/métodos , Solución Salina Hipertónica/administración & dosificación , Administración por Inhalación , Adulto , Monóxido de Carbono/administración & dosificación , Femenino , Humanos , Masculino , Pruebas de Función Respiratoria , Espirometría , Estadísticas no Paramétricas
8.
Indoor Air ; 28(4): 611-623, 2018 07.
Artículo en Inglés | MEDLINE | ID: mdl-29500848

RESUMEN

3D printers are increasingly run at home. Nanoparticle emissions from those printers have been reported, which raises the question whether adverse health effects from ultrafine particles (UFP) can be elicited by 3D printers. We exposed 26 healthy adults in a single-blinded, randomized, cross-over design to emissions of a desktop 3D printer using fused deposition modeling (FDM) for 1 hour (high UFP-emitting acrylonitrile butadiene styrene [ABS] vs low-emitting polylactic acid [PLA]). Before and after exposures, cytokines (IL-1ß, IL-6, TNF-α, INF-γ) and ECP in nasal secretions, exhaled nitric oxide (FeNO), urinary 8-isoprostaglandin F2α (8-iso PGF2α ), and self-reported symptoms were assessed. The exposures had no significant differential effect on 8-iso PGF2α and nasal biomarkers. However, there was a difference (P < .05) in the time course of FeNO, with higher levels after ABS exposure. Moreover, indisposition and odor nuisance were increased for ABS exposure. These data suggest that 1 hour of exposure to 3D printer emissions had no acute effect on inflammatory markers in nasal secretions and urine. The slight relative increase in FeNO after ABS printing compared to PLA might be due to eosinophilic inflammation from inhaled UFP particles. This possibility should be investigated in further studies using additional biomarkers and longer observation periods.


Asunto(s)
Resinas Acrílicas/efectos adversos , Butadienos/efectos adversos , Exposición a Riesgos Ambientales/análisis , Exposición por Inhalación/análisis , Poliésteres/efectos adversos , Poliestirenos/efectos adversos , Impresión Tridimensional , Adolescente , Adulto , Biomarcadores/análisis , Citocinas/análisis , Dinoprost/análogos & derivados , Dinoprost/orina , Exposición a Riesgos Ambientales/efectos adversos , Proteína Catiónica del Eosinófilo/análisis , Espiración , Femenino , Voluntarios Sanos , Humanos , Exposición por Inhalación/efectos adversos , Masculino , Nanopartículas/efectos adversos , Nanopartículas/análisis , Óxido Nítrico/análisis , Nariz , Tamaño de la Partícula , Adulto Joven
9.
J Clin Monit Comput ; 32(4): 753-761, 2018 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-29019006

RESUMEN

Electrical impedance tomography (EIT) has mostly been used in the Intensive Care Unit (ICU) to monitor ventilation distribution but is also promising for the diagnosis in spontaneously breathing patients with obstructive lung diseases. Beside tomographic images, several numerical measures have been proposed to quantitatively assess the lung state. In this study two common measures, the 'Global Inhomogeneity Index' and the 'Coefficient of Variation' were compared regarding their capability to reflect the severity of lung obstruction. A three-dimensional simulation model was used to simulate obstructed lungs, whereby images were reconstructed on a two-dimensional domain. Simulations revealed that minor obstructions are not adequately recognized in the reconstructed images and that obstruction above and below the electrode plane may result in misleading values of inhomogeneity measures. EIT measurements on several electrode planes are necessary to apply these measures in patients with obstructive lung diseases in a promising manner.


Asunto(s)
Impedancia Eléctrica , Enfermedades Pulmonares Obstructivas/diagnóstico por imagen , Tomografía/métodos , Simulación por Computador , Análisis de Elementos Finitos , Humanos , Procesamiento de Imagen Asistido por Computador , Unidades de Cuidados Intensivos , Enfermedades Pulmonares Obstructivas/fisiopatología , Masculino , Persona de Mediana Edad , Monitoreo Fisiológico/métodos , Monitoreo Fisiológico/estadística & datos numéricos , Respiración , Tomografía/estadística & datos numéricos
10.
Indoor Air ; 28(1): 112-124, 2018 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-28960517

RESUMEN

The possible impact of ultrafine particles from laser printers on human health is controversially discussed although there are persons reporting substantial symptoms in relation to these emissions. A randomized, single-blinded, cross-over experimental design with two exposure conditions (high-level and low-level exposure) was conducted with 23 healthy subjects, 14 subjects with mild asthma, and 15 persons reporting symptoms associated with laser printer emissions. To separate physiological and psychological effects, a secondary physiologically based categorization of susceptibility to particle effects was used. In line with results from physiological and biochemical assessments, we found no coherent, differential, or clinically relevant effects of different exposure conditions on subjective complaints and cognitive performance in terms of attention, short-term memory, and psychomotor performance. However, results regarding the psychological characteristics of participants and their situational perception confirm differences between the participants groups: Subjects reporting symptoms associated with laser printer emissions showed a higher psychological susceptibility for adverse reactions in line with previous results on persons with multiple chemical sensitivity or idiopathic environmental intolerance. In conclusion, acute psychological and cognitive effects of laser printer emissions were small and could be attributed only to different participant groups but not to differences in exposure conditions in terms of particle number concentrations.


Asunto(s)
Asma/etiología , Cognición/efectos de los fármacos , Material Particulado/efectos adversos , Impresión , Adulto , Contaminación del Aire Interior , Asma/psicología , Estudios de Casos y Controles , Estudios Cruzados , Femenino , Humanos , Tinta , Masculino , Persona de Mediana Edad , Distribución Aleatoria , Adulto Joven
11.
Indoor Air ; 27(4): 753-765, 2017 07.
Artículo en Inglés | MEDLINE | ID: mdl-28054389

RESUMEN

Ultrafine particles emitted from laser printers are suspected to elicit adverse health effects. We performed 75-minute exposures to emissions of laser printing devices (LPDs) in a standardized, randomized, cross-over manner in 23 healthy subjects, 14 mild, stable asthmatics, and 15 persons reporting symptoms associated with LPD emissions. Low-level exposures (LLE) ranged at the particle background (3000 cm-3 ) and high-level exposures (HLE) at 100 000 cm-3 . Examinations before and after exposures included spirometry, body plethysmography, transfer factors for CO and NO (TLCO, TLNO), bronchial and alveolar NO, cytokines in serum and nasal secretions (IL-1ß, IL-5, IL-6, IL-8, GM-CSF, IFNγ, TNFα), serum ECP, and IgE. Across all participants, no statistically significant changes occurred for lung mechanics and NO. There was a decrease in volume-related TLNO that was more pronounced in HLE, but the difference to LLE was not significant. ECP and IgE increased in the same way after exposures. Nasal IL-6 showed a higher increase after LLE. There was no coherent pattern regarding the responses in the participant subgroups or single sets of variables. In conclusion, the experimental acute responses to short but very high-level LPD exposures were small and did not indicate clinically relevant effects compared to low particle number concentrations.


Asunto(s)
Contaminantes Atmosféricos/efectos adversos , Contaminación del Aire Interior/efectos adversos , Biomarcadores/análisis , Interleucina-6/análisis , Pulmón/fisiopatología , Material Particulado/efectos adversos , Adolescente , Adulto , Contaminantes Atmosféricos/análisis , Análisis de Varianza , Asma , Periféricos de Computador , Femenino , Alemania , Humanos , Masculino , Persona de Mediana Edad , Tamaño de la Partícula , Material Particulado/análisis , Pletismografía , Espirometría , Adulto Joven
12.
Int Arch Occup Environ Health ; 89(6): 1017-24, 2016 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-27155612

RESUMEN

PURPOSE: Several epidemiological studies indicate that inhaled nitrogen dioxide (NO2) at low concentrations have been statistically associated with adverse health effects. However, these results are not reflected by exposure studies in humans. The aim of the study was to assess the acute functional and cellular responses to different NO2 concentrations in healthy human subjects with various techniques. METHODS: Twenty-five subjects were exposed for 3 h to NO2 concentrations 0, 0.1, 0.5, and 1.5 ppm in a randomized crossover study design during 4 consecutive weeks. In each subject, lung function, diffusion capacity and exhaled nitric oxide were measured and inflammation markers were assessed in blood, nasal secretions, induced sputum and exhaled breath condensate. RESULTS: From all lung function indices under consideration, only intrathoracic gas volume was borderline significantly increased after 0.5 ppm (p = 0.048) compared to 0.1 ppm NO2. Regarding the cellular effect parameters, the macrophage concentration in induced sputum decreased with increasing NO2 concentration, although these changes were only borderline significant (p = 0.05). CONCLUSION: These results do not suggest a considerable acute adverse response in human subjects after 3 h of exposure to NO2 in the NO2 concentration range investigated in this study.


Asunto(s)
Exposición por Inhalación/efectos adversos , Pulmón/efectos de los fármacos , Dióxido de Nitrógeno/toxicidad , Adolescente , Adulto , Estudios Cruzados , Femenino , Voluntarios Sanos , Humanos , Mediadores de Inflamación/análisis , Macrófagos/efectos de los fármacos , Masculino , Mucosa Nasal/efectos de los fármacos , Mucosa Nasal/metabolismo , Óxido Nítrico/análisis , Capacidad de Difusión Pulmonar/efectos de los fármacos , Eliminación Pulmonar/efectos de los fármacos , Pruebas de Función Respiratoria , Esputo/citología , Esputo/efectos de los fármacos , Adulto Joven
13.
Respir Med ; 111: 39-46, 2016 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-26725462

RESUMEN

BACKGROUND: Reliable up-to-date estimates regarding the economic impact of chronic obstructive pulmonary disease (COPD) are lacking. This study investigates COPD excess healthcare utilization, work absenteeism, and resulting costs within the German COPD cohort COSYCONET. METHODS: Data from 2139 COPD patients in GOLD grade 1-4 from COSYCONET were compared with 1537 lung-healthy control subjects from the population-based KORA platform. Multiple generalized linear models analyzed the association of COPD grades with healthcare utilization, work absence, and costs from a societal perspective while adjusting for sex, age, education, smoking status, body mass index (BMI), and several comorbidities. RESULTS: COPD was significantly associated with excess healthcare utilization, work absence, and premature retirement. Adjusted annual excess cost of COPD in 2012 for GOLD grade 1-4 amounted to €2595 [1770-3678], €3475 [2966-4102], €5955 [5191-6843], and €8924 [7190-10,853] for direct costs, and €8621 [4104-13,857], €9871 [7692-12,777], €16,550 [13,743-20,457], and €27,658 [22,275-35,777] for indirect costs respectively. Comorbidities contributed to the primary effect of COPD on direct costs only. An additional history of cancer or stroke had the largest effect on direct costs, but the effects were smaller than those of COPD grade 3/4. CONCLUSIONS: COPD is associated with substantially higher costs than previously reported.


Asunto(s)
Enfermedad Pulmonar Obstructiva Crónica/economía , Enfermedad Pulmonar Obstructiva Crónica/epidemiología , Absentismo , Adulto , Anciano , Anciano de 80 o más Años , Comorbilidad , Estudios Transversales , Femenino , Alemania/epidemiología , Costos de la Atención en Salud , Humanos , Masculino , Persona de Mediana Edad , Aceptación de la Atención de Salud , Estudios Prospectivos
14.
Pneumologie ; 69(3): 147-64, 2015 Mar.
Artículo en Alemán | MEDLINE | ID: mdl-25750095

RESUMEN

Spirometry is a simple test and considered the gold standard in lung function. An obstructive ventilatory defect is a disproportionate reduction of maximal airflow from the lung in relation to the maximal volume that can be displaced from the lung. It implies airway narrowing and is defined by a reduced FEV1/FVC ratio below the 5th percentile of the predicted value (lower limit of normal, LLN). A restrictive disorder may be suspected when vital capacity (FVC) is reduced and FEV1/FVC is normal. It is definitely proven, however, only by a decrease in TLC below the 5th percentile of predicted value (LLN). The measurement of TLC by body plethysmography is necessary to confirm or exclude a restrictive defect or hyperinflation of the lung when FVC is below the LLN. 2012 a task force of the ERS published new reference values based on 74,187 records from healthy non-smoking males and females from 26 countries. The new reference equations for the 3-95 age range are now available that include appropriate age-dependent mean values and lower limits of normal (LLN). This presentation aims at providing the reader with recommendations dealing with standardization and interpretation of spirometry.


Asunto(s)
Diagnóstico por Computador/normas , Medicina Ambiental/normas , Medicina del Trabajo/normas , Guías de Práctica Clínica como Asunto , Neumología/normas , Espirometría/normas , Alemania
15.
Int J Clin Pract ; 68(1): 130-8, 2014 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-24341307

RESUMEN

BACKGROUND: Anaemia is a frequent, clinically relevant condition in various chronic diseases. It seems also to be prevalent in patients with chronic respiratory failure (CRF). We studied the characteristics of anaemia in CRF and its associations with clinical outcome. METHODS: In a prospective design, 271 consecutive patients with CRF were evaluated; patients with other conditions often associated with anaemia were excluded. Haematological laboratory and physiological parameters, health-related quality of life (HRQL), dyspnoea and 48-month survival were determined. Anaemia was defined according to WHO [haemoglobin (Hb)< 13 g/l (male); Hb< 12 g/dl (female)] and using an established algorithm. RESULTS: Among 185 patients included, 18.4% showed anaemia, not depending on chronic obstructive pulmonary disease (COPD) vs. non-COPD (17.6% vs. 19.0%; p = 0.851) or on gender [16.5% (female) vs. 19.8% (male); p = 0.702]. Anaemic patients had higher age, creatinine (p < 0.05 each) and erythropoietin levels (p < 0.001), but lower transferrin saturation (TSAT), serum iron and vitamin B12 levels (p < 0.01 each). By definition, most anaemic patients (67.6%) had disturbances in iron homeostasis according to 'anaemia of chronic disease' and/or true iron deficiency anaemia. Hb was independently related to dyspnoea and HRQL, while TSAT ≥ 20% was linked to less dyspnoea and better subjective exercise capability. Non-survivors had lower Hb and serum iron levels (p < 0.05 each). In multivariate analysis, lower serum iron levels and TSAT were independently associated with mortality (p < 0.05 each). CONCLUSION: Anaemia was common in patients with CRF and often because of disturbed iron homeostasis. Hb and TSAT were linked to functional outcome and HRQL. Lower serum iron levels and TSAT were independent prognostic parameters.


Asunto(s)
Insuficiencia Respiratoria/complicaciones , Anciano , Anemia/sangre , Anemia/etiología , Anemia/mortalidad , Enfermedad Crónica , Métodos Epidemiológicos , Femenino , Hemoglobinas/metabolismo , Homeostasis/fisiología , Humanos , Masculino , Persona de Mediana Edad , Insuficiencia Respiratoria/sangre , Insuficiencia Respiratoria/mortalidad , Transferrina/metabolismo
16.
Int J Biometeorol ; 58(2): 249-62, 2014 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-24091656

RESUMEN

This study determined the influence of various meteorological variables and air pollutants on airway disorders in general, and asthma and/or chronic obstructive pulmonary disease in particular, in Munich, Bavaria, during 2006 and 2007. This was achieved through an evaluation of the daily frequency of calls to medical and emergency call centres, ambulatory medical care visits at general practitioners, and prescriptions of antibiotics for respiratory diseases. Meteorological parameters were extracted from data supplied by the European Centre for Medium Range Weather Forecast. Data on air pollutant levels were extracted from the air quality database of the European Environmental Agency for different measurement sites. In addition to descriptive analyses, a backward elimination procedure was performed to identify variables associated with medical outcome variables. Afterwards, generalised additive models (GAM) were used to verify whether the selected variables had a linear or nonlinear impact on the medical outcomes. The analyses demonstrated associations between environmental parameters and daily frequencies of different medical outcomes, such as visits at GPs and air pressure (-27 % per 10 hPa change) or ozone (-24 % per 10 µg/m(3) change). The results of the GAM indicated that the effects of some covariates, such as carbon monoxide on consultations at GPs, or humidity on medical calls in general, were nonlinear, while the type of association varied between medical outcomes. These data suggest that the multiple, complex effect of environmental factors on medical outcomes should not be assumed homogeneous or linear a priori and that different settings might be associated with different types of associations.


Asunto(s)
Contaminación del Aire/estadística & datos numéricos , Asma/epidemiología , Ambiente , Exposición a Riesgos Ambientales/estadística & datos numéricos , Enfermedad Pulmonar Obstructiva Crónica/epidemiología , Población Urbana/estadística & datos numéricos , Tiempo (Meteorología) , Adolescente , Adulto , Distribución por Edad , Anciano , Anciano de 80 o más Años , Causalidad , Niño , Preescolar , Femenino , Alemania/epidemiología , Humanos , Lactante , Recién Nacido , Masculino , Persona de Mediana Edad , Prevalencia , Factores de Riesgo , Distribución por Sexo , Adulto Joven
17.
Indoor Air ; 22(2): 148-58, 2012 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-21913995

RESUMEN

UNLABELLED: Outdoor particulate matter (PM(10)) is associated with detrimental health effects. However, individual PM(10) exposure occurs mostly indoors. We therefore compared the toxic effects of classroom, outdoor, and residential PM(10). Indoor and outdoor PM(10) was collected from six schools in Munich during teaching hours and in six homes. Particles were analyzed by scanning electron microscopy and X-ray spectroscopy (EDX). Toxicity was evaluated in human primary keratinocytes, lung epithelial cells and after metabolic activation by several human cytochromes P450. We found that PM(10) concentrations during teaching hours were 5.6-times higher than outdoors (117 ± 48 µg/m(3) vs. 21 ± 15 µg/m(3), P < 0.001). Compared to outdoors, indoor PM contained more silicate (36% of particle number), organic (29%, probably originating from human skin), and Ca-carbonate particles (12%, probably originating from paper). Outdoor PM contained more Ca-sulfate particles (38%). Indoor PM at 6 µg/cm(2) (10 µg/ml) caused toxicity in keratinocytes and in cells expressing CYP2B6 and CYP3A4. Toxicity by CYP2B6 was abolished with the reactive oxygen species scavenger N-acetylcysteine. We concluded that outdoor PM(10) and indoor PM(10) from homes were devoid of toxicity. Indoor PM(10) was elevated, chemically different and toxicologically more active than outdoor PM(10). Whether the effects translate into a significant health risk needs to be determined. Until then, we suggest better ventilation as a sensible option. PRACTICAL IMPLICATIONS: Indoor air PM(10) on an equal weight base is toxicologically more active than outdoor PM(10). In addition, indoor PM(10) concentrations are about six times higher than outdoor air. Thus, ventilation of classrooms with outdoor air will improve air quality and is likely to provide a health benefit. It is also easier than cleaning PM(10) from indoor air, which has proven to be tedious.


Asunto(s)
Contaminación del Aire Interior/efectos adversos , Contaminación del Aire Interior/análisis , Material Particulado/análisis , Material Particulado/toxicidad , Hidrocarburo de Aril Hidroxilasas/metabolismo , Biotransformación , Carbonato de Calcio/análisis , Carbonato de Calcio/toxicidad , Línea Celular , Células Cultivadas , Niño , Citocromo P-450 CYP2B6 , Citocromo P-450 CYP3A/metabolismo , Alemania , Vivienda , Humanos , Queratinocitos/efectos de los fármacos , Queratinocitos/metabolismo , Microscopía Electrónica de Rastreo , Oxidorreductasas N-Desmetilantes/metabolismo , Tamaño de la Partícula , Instituciones Académicas , Silicio/análisis , Silicio/toxicidad , Azufre/análisis , Azufre/toxicidad
18.
Respir Med ; 105(7): 959-71, 2011 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-21356587

RESUMEN

Body plethysmography allows to assess functional residual capacity (FRC(pleth)) and specific airway resistance (sRaw) as primary measures. In combination with deep expirations and inspirations, total lung capacity (TLC) and residual volume (RV) can be determined. Airway resistance (Raw) is calculated as the ratio of sRaw to FRC(pleth). Raw is a measure of airway obstruction and indicates the alveolar pressure needed to establish a flow rate of 1 L s(-1). In contrast, sRaw can be interpreted as the work to be performed by volume displacement to establish this flow rate. These measures represent different functional aspects and should both be considered. The measurement relies on the fact that generation of airflow needs generation of pressure. Pressure generation means that a mass of air is compressed or decompressed relative to its equilibrium volume. This difference is called "shift volume". As the body box is sealed and has rigid walls, its free volume experiences the same, mirror image-like shift volume as the lung. This shift volume can be measured via the variation of box pressure. The relationship between shift volume and alveolar pressure is assessed in a shutter maneuver, by identifying mouth and alveolar pressure under zero-flow conditions. These variables are combined to obtain FRC(pleth), sRaw and Raw. This presentation aims at providing the reader with a thorough and precise but non-technical understanding of the working principle of body plethysmography. It also aims at showing that this method yields significant additional information compared to spirometry and even bears a potential for further development.


Asunto(s)
Obstrucción de las Vías Aéreas/fisiopatología , Resistencia de las Vías Respiratorias/fisiología , Capacidad Residual Funcional/fisiología , Pletismografía Total/instrumentación , Capacidad Pulmonar Total/fisiología , Humanos , Espirometría/instrumentación
19.
Pneumologie ; 65(8): 465-70, 2011 Aug.
Artículo en Alemán | MEDLINE | ID: mdl-21437859

RESUMEN

BACKGROUND: Volatile organic compounds (VOCs) can be used as biomarkers in exhaled air. VOC profiles can be detected by an array of nanosensors of an electronic nose. These profiles can be analysed using bioinformatics. It is, however, not known whether different devices of the same model measure identically and to which extent different set-ups and the humidity of the inhaled air influence the VOC profile. METHODS: Three different measuring set-ups were designed and three healthy control subjects were measured with each of them, using four devices of the same model (Cyranose 320™, Smiths Detection). The exhaled air was collected in a plastic bag. Either ambient air was used as reference (set-up Leipzig), or the reference air was humidified (100% relative humidity) (set-up Marburg and set-up Munich). In the set-up Marburg the subjects inhaled standardised medical air (Aer medicinalis Linde, AGA AB) out of a compressed air bottle through a demand valve; this air (after humidification) was also used as reference. In the set-up Leipzig the subjects inhaled VOC-filtered ambient air, in the set-up Munich unfiltered room air. The data were evaluated using either the real-time data or the changes in resistance as calculated by the device. RESULTS: The results were clearly dependent on the set-up. Apparently, humidification of the reference air could reduce the variance between devices, but this result was also dependent on the evaluation method used. When comparing the three subjects, the set-ups Munich and Marburg mapped these in a similar way, whereas not only the signals but also the variance of the set-up Leipzig were larger. CONCLUSION: Measuring VOCs with an electronic nose has not yet been standardised and the set-up significantly affects the results. As other researchers use further methods, it is currently not possible to draw generally accepted conclusions. More systematic tests are required to find the most sensitive and reliable but still feasible set-up so that comparability is improved.


Asunto(s)
Contaminantes Ocupacionales del Aire/análisis , Técnicas Biosensibles/instrumentación , Pruebas Respiratorias/instrumentación , Compuestos Orgánicos Volátiles/análisis , Adulto , Gráficos por Computador , Diseño de Equipo , Femenino , Humanos , Humedad , Masculino , Microcomputadores , Persona de Mediana Edad , Sensibilidad y Especificidad
20.
Pneumologie ; 65(7): 401-5, 2011 Jul.
Artículo en Alemán | MEDLINE | ID: mdl-21412705

RESUMEN

Non-invasive pulmonary diagnostics is a promising and interesting field in respiratory medicine. Beside exhaled breath condensate, there is an increasing interest in alternative and faster techniques such as electronic noses (EN). EN aim to mimic or improve the sense of smelling. Different types of EN have been employed in research so far. In addition to ion mobility spectrometry and mass spectrometry, ENs that consist of various biopolymer sensors for the sensing of volatile organic compounds (VOCs) have been tested. VOCs bind to the sensors depending on size, structure, hydrogen binding and polarity. This leads to physical alterations, e. g., swelling resulting in a change of resistance. The smell print represents composite patterns in contrast to single compounds, and the distinction between different categories is achieved by pattern recognition algorithms. Other types of EN like mass spectrometry and ion mobility spectrometry are capable of identifying even single analyte fractions provided that their characteristics have been saved in data repositories. The non-invasive nature, onsite availability and relatively cheap sampling are advantages of ENs that underly the increasing interest in their use for medical purposes. Some promising results have already been published. This review aims to describe the state of the art in brief form.


Asunto(s)
Materiales Biomiméticos , Técnicas Biosensibles , Pruebas Respiratorias/instrumentación , Gases/análisis , Enfermedades Pulmonares/diagnóstico , Olfato , Compuestos Orgánicos Volátiles/análisis , Biomarcadores/análisis , Humanos , Enfermedades Pulmonares/metabolismo
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...